Page 2 general each of these diagrams shows the wiring for a particular module or card or base which can be used with the as44281 version of the simplex 4100u fire alarm system. Initiating devices monitor zam notification appliance circuits signal zam control relays control zam these zams are compatible with the following simplex fire alarm control panels when equipped with mapnet ii communications.
Simplex Class B Wiring Diagram Amplifier Switch
Simplex zam wiring diagram. Box 19545 christchurch 64 3 3895096 new zealand. Basic wiring on a simplex 4010 fire alarm control panel. Organisation each diagram has a 3 digit sheet number from the drawing. Idnet and mapnet ii wiring are supervised and power limited. Monitor zam wiring diagramswiring diagrams are shown in the following illustrations. Control zam reference wiring diagram 24 vdc shield n.
Refer to field wiring diagram 842 073 for further information on wiring monitor zams to idnet. 1 common 2 control power controlled device t tapped or inout wiring control zam no. Refer to field wiring diagram 842 073 for further information on wiring supervised iams to idnet. Control zam reference wiring diagram 24 vdc shield simplex the simplex logo and mapnet ii are. 2 mapnet ii communications application resistive rating inductive rating power limited 2 a at 28 vdc 1 a at 28 vdc non power limited 2 a at 28 vdc 1 a at 28 vdc 12 a at 120. Supervised iam connections 2 3.
This video is about control zam wiring i get a lot of questions on how to wire the control zam since the terminals are not marked. 1 common 1 no. Refer to field wiring diagrams 841 804 or 841 996 for further information on wiring monitor zams to mapnet ii. Monitor zam connections 2 3 setting the monitor zams address. Signal zam 4090 9007 4100es signal zam 4090 9007 wiring fire protection products wiring diagram tyco fire protection products 17 mary muller drive 1976 181 po. Output capacity is up to 2 a at 24 vdc or 50 w of 25 vrms speakers or up to three simultaneously activated firefighter phones.
Idnet and mapnet ii wiring are supervised and power limited. Multi application peripherals and accessories communicating devices inout wiring signal input audio or phone simplex time rec. Refer to field wiring diagrams 841 804 or 841 996 for further information on wiring supervised iams to mapnet ii. 41004100u series fire alarm control panels 4100 series universal transponders. A model typical supervised iam wiring diagrams mapnet ii. Control zam reference wiring diagram 24 vdc shield simplex the simplex logo and mapnet ii are.
Page 1 fire 4100u fire indicator panel australian wiring diagrams australian australian installation wiring diagrams manual lt0432 iss 104. Signal zams are used to supervise and operate 24 vdc notification appliances speakers and telephone circuits. 4010 facp idnet channel figure 3. Es s1 fire indicator panel installation maintenance australian installation and other information shown were current as of document revision date and are subject to change without notice.