Qs system qse ci dmx control interfaces 369372 rev. 500r 1000r or 2000r models note.
Qs Dmx Control Interface Mr Resistor
Lutron qse ci dmx wiring diagram. The qs wired communications link is limited to 100 devices and 512 switch legs each dmx channel 1 switch leg. The qse ci dmx consumes 2 power draw units on the qs link. Lutron grafik eye qs control unit qse ci dmx selv pelv nec class 2 qs link wiring for system communication dmx output. A 7 121510 powering the qse ci dmx power for one qse ci dmx counts as two devices toward the maximum of three devices per grafik eye qs control unit when powered off of pin 2 of the grafik eye qs. Lut dmx dmx output yes yes yes qse ci dmx dmx output yes qse io contact closure output yes yes grx io contact closure output yes omx io contact closure output yes yes hw cco 8 contact closure output yes omx ci rs232 rs232ethernet output yes homeworks p5 processor rs232ethernet output yes. Selv pelv necr class 2 wiring with line voltagemains wiring.
Dmx 512 link wiring qse ci dmx control interface installation and operation instructions 3 connect the dmx link terminals on the qse ci dmx interface to input terminals on dmx512 controlled equipment. Lutrons new facility management tool empowers you to manage your building from anywhere. B 7 081211 powering the qse ci dmx power for one qse ci dmx counts as two devices toward the maximum of three devices per grafik eye qs control unit when powered off of pin 2 of the grafik eye qs. Each feature is designed around what is most important to you how well your building is working. The maximum wiring length for the qs link is 2000 ft 610 m. Another option is to power the qse ci dmx from a qs link power supply qsps p1 1 50.
Each terminal accepts up to two 18 awg 10 mm2 wires. Qs system qse ci dmx control interfaces 369372 rev. Link must be 1000 feet 305 m or less. Wiring diagram is not applicable to. 32 dmx channels per qse ci dmx control interface. Each qse ci nwk e control interface counts as 1 device and 0 zones.
The qse ci dmx converts the zone intensities for that scene into dmx512 channel settings. 7 wire occ sensor with photocell. Each terminal on the qse ci dmx accepts two 18 awg 10 mm2 wires. Another option is to power the qse ci dmx from a qs link power supply qsps p1 1 50. Follow all local and national electrical codes when installing 2 connectivity please refer to the wiring diagrams below. Easily monitor control and optimize a lutron control system from any tablet pc or smartphone.
The rgb led fixture will go to the color programmed for that scene and the stage light will go to the desired intensity. Each qse ci nwk e control interface consumes 2 power draw units pdu on the qs link.

















