Turn off all electrical power to the appliance. If it has a reset on it push it and it just might reset the damper.
Best Ans Boilers Ideas And Get Free Shipping 22hbc4ej
Effikal rvgp ksf wiring diagram. Opened for pics your motor is new boxed. Field controls ovd 7 7 automatic oil vent damper 24v 46561707. Wiring errors can cause improper and dangerous operation. Field formerly effikal vent damper wiring harness rvgp ks. Keep boiler area clean and free from combustible materials gasoline and other flammable vapors and liquids. Wiring diagram 118119 series controls.
16750 shipping. When equipped with effikal vent damper model rvgp place service switch in hold damper open position. This fits all size rvgp ks vent dampers use your existing assembly wiring harness or universal harness. Checking and adjusting warning. 2 servicing should only be performed by a qualified service technician introduction this service handbook covers the water heater model and series numbers listed on. This is the only motor made for effikal vent dampers.
The vent damper date code is located on a sticker under the motor assembly cap on the plastic base. Effikal rvgp ksf series flue damper troubleshooting guide. Field controls 46491600 gma pl vent damper motor assembly plastic base. Field formerly effikal vent damper motor rvgp ks. This will save half the cost of replacing the entire assembly. All sizes and models of the rvgp pc have the same motor assembly with black effikal caps and black plastic bases.
If all steps have been tried and damper problems persists contact state water heaters 800 365 8170. Effikal rvgp ksf series flue damper troubleshooting guide see figure on front page of this insert sheet important. Device must be installed by a qualified installer in compliance with local codes or the national fuel gas code ansi z2231 nfpa 54 or cancga b149 and the national electric code ansi c1 nfpa 70. Follow the wiring from the damper and you should find it. Mine is a effikal model no. Serial numbers are located on a label on the side of the dampers cap.
4950 shipping. There is an automatic. Damper must be open before combustion takes place. Field controls 46491600 vent damper motor assembly plastic base this field controls replacement motor with plastic base takes only a few minutes to install. When servicing controls all wires must be labeled prior to disconnection. Field formerly effikal vent damper 46487001 5 inch.
Failure to follow this warning could result in explosion fire personal injury or death. It goes without saying its not safe to let kids play with any boiler controls or the thermostat. Test for 24vac between black and orange on damper pc. Rvgp pc 7bkf and it has a switch on the back of motor housing. Maintenance procedures in addition the maintenance and care of the boiler designated on page 3 and explained on the following pages must be performed to assure maximum boiler. It allows you to replace a defective motor without replacing an entire unit.