Securitron bps 24 2 power supply 24vdc 2amp recommended where an interface with a fire alarm system or battery backup is needed. Wiring for bps 12 1 and bps 24 1.
Differentiation Drives Widespread Rewiring Of The Neural Stem
Bps 12 24 1 wiring diagram. Bps 12 1 and bps 24 1 operation and installation instructions. A battery pack of the appropriate voltage see. 30 documents similar to martechnicltd bnwas u was usermanual 1 kenr uploaded by. Connect the pushbutton com 2 to the power supply positive then connect the no 2 of the pushbutton to the keypad rex input. Ed40005000 x m94 x 6900 powermatic x mag x dk 11 x 1 wall plates interior. Make sure power supply.
Note that a special version of the bps 1224 1 operates on 220 vac input. The power supply can be used with or without them. Supplies 1 full amp continuous current output even while charging back up batteries. Batteries are an option. For c ul listed applications the unit shall be installed in accordance with part 1 of the canadian electrical code. Bpss 10 bpss 20 installation and operating instructions.
Bpsm 12 6 9 and 15. The bps 1224 1 is ul class 2 listed. Ed 40005000 m94 x dk11 x bps 24 1 pair doors. Battery charging capability the bps 12 1 or bps 24 1 power supply incorporates a battery charging circuit appropriate for standby rated sealed l ead acid or gel cell batteries. Local building department to make sure you are complying with applicable wiring codes before installing these units. Bps 24 2 3 4 6 and 10 operation and installation instructions.
The bps linear power supply delivers more current than psps and all bps models are ul class 2 listed allowing for wire runs without the use of conduit from power supply to door. Ccm 1 ccm 1n installation and operating. Safe for use with readers electric strikes and maglocks these units interface to fire alarm systems and provide battery backup. Dual output field selectable 12 or 24vdc via clearly marked toggle switch. Time period reset units and external alarm devices have been connected correctly according to wiring diagram shows text 1 after a short intro procedure. Bps 12 3 45 6 9 and 15.
24 vdc capacity outputs cabinet size 1 4 4 8 8 8 12x9x4 14x14x4 14x14x4 15x18x6 15x18x6 15x18x6 bps 24 1 bps 24 2 bps 24 3 bps 24 4 bps 24 6 bps 24 10 1 amp 2 amp 3 amp 4 amp 6 amp 10 amp. Bpsm 24 4 6 and 10 operation and installation instructions. Black stripe black red red whtred red white black whtblu blue orange green. The bps 1224 1 is ul class 2 listed allowing for wire runs without the use of conduit from power supply to door. The bps series of power supplies delivers linear technology recommended by most manufacturers of sensitive electronic access control and security components. Ed40005000 x m94 x dk11 x bps 24 1.
Discontinued product literature. Wiring diagrams and instructions. Bps 1 amp c no nc rex dk 12 magnalock nc 1 no 2 com 1 com 2 pb3er fail safe wiring with rex.